Testsealabs Urine Drug Met MET Rapid Test
[INTRODUCTION]
MET is an addictive stimulant drug that strongly activates certain systems in the brain. MET is closely related chemically to amphetamine, but the central nervous system effects of MET are greater. MET is made in illegal laboratories and has a high potential for abuse and dependence. The drug can be taken orally, injected, or inhaled. Acute higher doses lead to enhanced stimulation of the central nervous system and induce euphoria, alertness, reduced appetite, and a sense of increased energy and power. Cardiovascular responses to MET include increased blood pressure and cardiac arrhythmias. More acute responses produce anxiety, paranoia, hallucinations, psychotic behavior, and eventually, depression and exhaustion.
The effects of MET generally last 2-4 hours and the drug has a half-life of 9-24 hours in the body. MET is excreted in the urine primarily as amphetamine and oxidized and deaminated derivatives. However, 10-20% of MET is excreted unchanged. Thus, the presence of the parent compound in the urine indicates MET use. MET is generally detectable in the urine for 3-5 days, depending on urine pH level.
The MET MET Test (Urine) yields a positive result when the concentration of methamphetamine in urine exceeds 1,000ng/ml.
[Materials Provided ]
1.FYL Test Device (strip/cassette/dipcard format)
2. Instructions for use
[Materials required, not Provided]
1. Urine collection container
2. Timer or clock
[Storage Conditions And Shelf Life]
1.Store as packaged in the sealed pouch at room temperature (2-30℃ or 36-86℉). The kit is stable within the expiration date printed on the labeling.
2.Once open the pouch, the test should be used within one hour. Prolonged exposure to hot and humid environment will cause product deterioration.
[Testing Method]
Allow the test and urine samples to equilibrate to room temperature (15-30℃or 59-86℉) prior to testing.
1. Remove the test cassette from the sealed pouch.
2. Hold the dropper vertically and transfer 3 full drops (approx. 100ml) of urine to the specimen well of the test cassette, and then begin timing. See the illustration below.
Wait for colored lines to appear. Interpret the test results at 3-5 minutes. Do not read results after 10 minutes.
[Materials Provided ]
1.FYL Test Device (strip/cassette/dipcard format)
2. Instructions for use
[Materials required, not Provided]
1. Urine collection container
2. Timer or clock
[Storage Conditions And Shelf Life]
1.Store as packaged in the sealed pouch at room temperature (2-30℃ or 36-86℉). The kit is stable within the expiration date printed on the labeling.
2.Once open the pouch, the test should be used within one hour. Prolonged exposure to hot and humid environment will cause product deterioration.
[Testing Method]
Allow the test and urine samples to equilibrate to room temperature (15-30℃or 59-86℉) prior to testing.
1. Remove the test cassette from the sealed pouch.
2. Hold the dropper vertically and transfer 3 full drops (approx. 100ml) of urine to the specimen well of the test cassette, and then begin timing. See the illustration below.
3. Wait for colored lines to appear. Interpret the test results at 3-5 minutes. Do not read results after 10 minutes.
[Results interpretation]
Negative: *Two lines appear. One red line should be in the control region (C), and another apparent red or pink line adjacent should be in the test region (T). This negative result indicates that the drug concentration is below the detectable level.
*NOTE: The shade of red in the test line region (T) will vary, but it should be considered negative whenever there is even a faint pink line.
Positive: One red line appears in the control region (C). No line appears in the test region (T). This positive result indicates that the drug concentration is above the detectable level.
Invalid: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test using a new test panel. If the problem persists, discontinue using the lot immediately and contact your local distributor.
[You may be interesting in the products information belows]
TESTSEALABS Rapid Single/Multi-drug Test Dipcard/Cup is a rapid, screening test for the qualitative detection of single/multiple drugs and drug metabolites in human urine at specified cut off levels.
* Specification Types Available
√Complete 15-drug product line
√Cut-off levels meet SAMSHA standards when applicable
√Results in minutes
√Multi options formats--strip,l cassette , panel and cup
√ Multi-drug device format
√6 drug combo( AMP,COC, MET, OPI, PCP, THC)
√ Many Different combinations available
√ Provide immediate evidence of potential adulteration
√6 Testing parameters: creatinine, nitrite, glutaraldehyde, PH, Specific gravity and oxidants/pyridinium chlorochromate
Product Name | Specimens | Formats | Cut off | Packing |
AMP Amphetamine Test | Urine | Strip/Cassette/Dipcard | 300/1000ng/ml | 25T/40T |
MOP Morphine Test | Urine | Strip/Cassette/Dipcard | 300ng/ml | 25T/40T |
MET MET Test | Urine | Strip/Cassette/Dipcard | 300/500/1000ng/ml | 25T/40T |
THC Marijuana Test | Urine | Strip/Cassette/Dipcard | 50ng/ml | 25T/40T |
KET KET Test | Urine | Strip/Cassette/Dipcard | 1000ng/ml | 25T/40T |
MDMA Ecstasy Test | Urine | Strip/Cassette/Dipcard | 500ng/ml | 25T/40T |
COC Cocaine Test | Urine | Strip/Cassette/Dipcard | 150/300ng/ml | 25T/40T |
BZO Benzodiazepines Test | Urine | Strip/Cassette/Dipcard | 300ng/ml | 25T/40T |
K2 Synthetic Cannabis Test | Urine | Strip/Cassette/Dipcard | 200ng/ml | 25T/40T |
BAR Barbiturates Test | Urine | Strip/Cassette/Dipcard | 300ng/ml | 25T/40T |
BUP Buprenorphine Test | Urine | Strip/Cassette/Dipcard | 10ng/ml | 25T/40T |
COT Cotinine Test | Urine | Strip/Cassette/Dipcard | 50ng/ml | 25T/40T |
EDDP Methaqualone Test | Urine | Strip/Cassette/Dipcard | 100ng/ml | 25T/40T |
FYL Fentanyl Test | Urine | Strip/Cassette/Dipcard | 200ng/ml | 25T/40T |
MTD Methadone Test | Urine | Strip/Cassette/Dipcard | 300ng/ml | 25T/40T |
OPI Opiate Test | Urine | Strip/Cassette/Dipcard | 2000ng/ml | 25T/40T |
OXY Oxycodone Test | Urine | Strip/Cassette/Dipcard | 100ng/ml | 25T/40T |
PCP Phencyclidine Test | Urine | Strip/Cassette/Dipcard | 25ng/ml | 25T/40T |
TCA Tricyclic Antidepressants Test | Urine | Strip/Cassette/Dipcard | 100/300ng/ml | 25T/40T |
TRA Tramadol Test | Urine | Strip/Cassette/Dipcard | 100/300ng/ml | 25T/40T |
Multi-Drug Single-Line Panel | Urine | 2-14 Drugs | See Insert | 25T |
Multi-Drug Device | Urine | 2-14 Drugs | See Insert | 25T |
Drug Test Cup | Urine | 2-14 Drugs | See Insert | 1T |
Oral-Fluid Multi-Drug Device | Saliva | 6 Drugs | See Insert | 25T |
Urine AdulterationStrips(Creatinine/Nitrite/Glutaraldehyde/PH/Specific Gravity/Oxidant | Urine | 6 Parameter Strip | See Insert | 25T |