Rapid Delivery for 2019 Novel Coronavirus Rapid Test - COVID-19 IgG/IgM Antibody Test(Colloidal Gold) – TESTSEA
Rapid Delivery for 2019 Novel Coronavirus Rapid Test - COVID-19 IgG/IgM Antibody Test(Colloidal Gold) – TESTSEA Detail:
【INTENDED USE】
Testsealabs®COVID-19 IgG/IgM Antibody Test Cassette is a lateral flow chromatographic immunoassay for the qualitative detection of IgG and IgM antibodies to COVID-19 in human whole blood, serum or plasma specimen.
【Specification】
20pc/box (20 test devices+ 20 tubes+1buffer+1 product insert)
【MATERIALS PROVIDED】
1.Test Devices
2.Buffer
3.Droppers
4.Product Insert
【SPECIMENS COLLECTION】
SARS-CoV2(COVID-19)IgG/IgM AntibodyTest Cassette (Whole Blood/Serum/ Plasma) can be performed usinghole blood (from venipuncture or fingerstick), serum or plasma.
1.To collect Fingerstick Whole Blood Specimens:
2.Wash the patient’s hand with soap and warm water or clean with an alcohol swab. Allow to dry.
3.Massage the hand without touching the puncture site by rubbing down the hand towardsthe fingertip of the middle or ring finger.
4.Puncture the skin with a sterile lancet. Wipe away the first sign of blood.
5.Gently rub the hand from wrist to palm to finger to form a rounded drop of blood over the puncture site.
6.Add the Fingerstick Whole Blood specimen to the test by using a capillary tube:
7.Touch the end of the capillary tube to the blood until filled to approximately 10mL. Avoid air bubbles.
8.Separate serum or plasma from blood as soon as possible to avoid hemolysis. Use only clear non- hemolyzed specimens.
【HOW TO TEST】
Allow the test, specimen, buffer and/or controls to reach room temperature (15-30°C) prior to testing.
Remove the test cassette from the foil pouch and use it within one hour. Best results will be obtained if the test is performed immediately after opening the foil pouch.
Place the cassette on a clean and level surface. For Serum or Plasma specimen:
- To use a dropper: Hold the dropper vertically, draw the specimen to the fill line (approximately 10mL), and transfer the specimen to the specimen well (S), then add 2 drops of buffer (approximately 80 mL), and start the timer.
- To use a pipette: To transfer 10 mL of specimen to the specimen well(S), then add 2 drops of buffer (approximately 80 mL), and start the timer
For Venipuncture Whole Blood specimen:
- To use a dropper: Hold the dropper vertically, draw the specimen about 1 cm above the fill line and transfer 1 full drop (approx. 10μL) of specimen to the sample well(S). Then add 2 drops of buffer (approximately 80 mL) and start the timer.
- To use a pipette: To transfer 10 mL of whole blood to the specimen well(S), then add 2 drops of buffer (approximately 80 mL), and start the timer
- For Fingerstick Whole Blood specimen:
- To use a dropper: Hold the dropper vertically, draw the specimen about 1 cm above the fill line and transfer 1 full drop (approx. 10μL) of specimen to the sample well(S). Then add 2 drops of buffer (approximately 80 mL) and start the timer.
- To use a capillary tube: Fill the capillary tube and transfer approximately 10mL of fingerstick whole blood specimen to the specimen well (S) of test cassette, then add 2 drops of buffer (approximately 80 mL) and start the timer. See illustration below.
- Wait for the colored line(s) to appear. Read results at 15 minutes. Do not interpret the result after 20 minutes.
- Note: It is suggested not to use the buffer, beyond 6 months after opening the vial.
【INTERPRETATION OF RESULTS】
IgG POSITIVE:* Two colored lines appear. One colored line should always appear in the control line region (C) and another line should be in the IgG line region.
IgM POSITIVE:* Two colored lines appear. One colored line should always appear in the control line region (C) and another line should be in the IgM line region.
IgG and IgM POSITIVE:* Three colored lines appear. One colored line should always appear in the control line region (C) and two test lines should be in the IgG line region and IgM lineregion.
*NOTE: The intensity of the color in the test line regions may vary depending on the concentration of COVID-19 antibodies present in the specimen. Therefore, any shade of color in the test line region should be considered positive.
NEGATIVE: One colored line appears in the control line region (C). No line appears in the IgG region and IgM region.
INVALID: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure an test with a new test. If the problem persists, discontinue using the test kit immediately and contact your local distributor.
Product detail pictures:
Related Product Guide:
"Sincerity, Innovation, Rigorousness, and Efficiency" will be the persistent conception of our company to the long-term to establish together with customers for mutual reciprocity and mutual gain for Rapid Delivery for 2019 Novel Coronavirus Rapid Test - COVID-19 IgG/IgM Antibody Test(Colloidal Gold) – TESTSEA, The product will supply to all over the world, such as: Chicago, Rio de Janeiro, United Kingdom, As a way to make use of the resource on the expanding information and facts in international trade, we welcome prospects from everywhere on the web and offline. In spite in the top quality products we offer, effective and satisfying consultation service is supplied by our specialist after-sale service group. Solution lists and detailed parameters and any other info weil be sent to you timely for the inquiries. So please get in touch with us by sending us emails or contact us if you have any concerns about our firm. ou can also get our address info from our web site and come to our enterprise. or a field survey of our solutions. We're confident that we are going to share mutual results and build solid co-operation relations with our companions in this market. We're looking forward to your inquiries.