OEM manufacturer Rapid Diagnostic Kit For Malaria - Testsea Disease Test TYP Typhoid IgG/IgM Rapid Test Kit – TESTSEA

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

The key to our success is "Good Product Quality, Reasonable Value and Efficient Service" for Noval Coronavirus Test Kit , 2019-Ncov Rapid Test , Coronavirus Test , Therefore, we can meet different inquiries from different consumers. You should find our web page to check additional info from our products.
OEM manufacturer Rapid Diagnostic Kit For Malaria - Testsea Disease Test TYP Typhoid IgG/IgM Rapid Test Kit – TESTSEA Detail:

Brand Name:

testsea

Product name:

TYP Typhoid IgG/IgM 

Place of Origin:

Zhejiang, China

Type:

Pathological Analysis Equipments

Certificate:

ISO9001/13485

Instrument classification

Class II

Accuracy:

99.6%

Specimen:

Whole Blood/Serum/Plasma

Format:

Cassete/Strip

Specification:

3.00mm/4.00mm

MOQ:

1000 Pcs

Shelf life:

2 years

HIV 382

The clinical diagnosis of typhoid fever depends on the isolation of S. typhi from blood, bone marrow or a specific anatomic lesion. In the facilities that can not afford to perform this complicated and timeconsuming procedure, Filix-Widal test is used to facilitate the diagnosis. However, many limitations lead to difficulties in the interpretation of the Widal test3,4. 

In contrast, the Typhoid IgG/IgM Rapid Test is a simple and rapid laboratory test. The test simultaneously detects and differentiates the IgG and the IgM antibodies to S. typhi specific antigen5 t in whole blood specimen thus aid in the determination of current or previous exposure to the S. typhi.

Allow the test, specimen, buffer and/or controls to reach room temperature 15-30℃ (59-86℉) prior to testing.

1. Bring the pouch to room temperature before opening it. Remove the test device from the sealed pouch and use it as soon as possible.
2. Place the test device on a clean and level surface.
3. For serum or plasma specimen: Hold the dropper vertically and transfer 3 drops of serum or plasma (approximately 100μl) to the specimen well(S) of the test device, then start the timer. See illustration below.
4. For whole blood specimens: Hold the dropper vertically and transfer 1 drop of whole blood(approximately 35μl) to the specimen well(S) of the test device, then add 2 drops of buffer (approximately 70μl) and start the timer. See illustration below.  
5. Wait for the colored line(s) to appear. Read results at 15 minutes. Do not interpret the result after 20 minutes.  

Applying sufficient amount of specimen is essential for a valid test result. If migration (the wetting of membrane) is not observed in the test window after one minute, add one more drop of buffer (for whole blood) or specimen (for serum or plasma) to the specimen well.

Interpretation of Results

Positive: Two lines appear. One line should always appear in the control line region(C), and another one apparent colored line should appear in the test line region.

Negative: One colored line appears in the control region(C).No apparent colored line appear in the test line region.

Invalid: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure.

★ Review the procedure and repeat the test with a new test device. If the problem persists, discontinue using the test kit immediately and contact your local distributor.

Honorary certificate

Exhibition Information (6)


Product detail pictures:

OEM manufacturer Rapid Diagnostic Kit For Malaria - Testsea Disease Test TYP Typhoid IgG/IgM Rapid Test Kit – TESTSEA detail pictures

OEM manufacturer Rapid Diagnostic Kit For Malaria - Testsea Disease Test TYP Typhoid IgG/IgM Rapid Test Kit – TESTSEA detail pictures

OEM manufacturer Rapid Diagnostic Kit For Malaria - Testsea Disease Test TYP Typhoid IgG/IgM Rapid Test Kit – TESTSEA detail pictures


Related Product Guide:

Our firm aims to operating faithfully, serving to all of our shoppers , and working in new technology and new machine regularly for OEM manufacturer Rapid Diagnostic Kit For Malaria - Testsea Disease Test TYP Typhoid IgG/IgM Rapid Test Kit – TESTSEA, The product will supply to all over the world, such as: Malawi, Munich, French, So far our products have been exported to east Europe, the Middle East, Southeast, Africa and South America etc. We have 13years professional sales and purchase in Isuzu parts at home and abroad and the ownership of the modernized electronic Isuzu parts checking systems. We honor our core principal of Honesty in business, priority in service and will do our best to offer our customers with high quality products and excellent service.
  • Company director has very rich management experience and strict attitude, sales staff are warm and cheerful, technical staff are professional and responsible,so we have no worry about product,a nice manufacturer.
    5 Stars By Maggie from Rome - 2018.12.11 11:26
    We are really happy to find such a manufacturer that ensuring product quality at the same time the price is very cheap.
    5 Stars By David Eagleson from Bolivia - 2017.06.29 18:55

    Send your message to us:

    Send your message to us:

    Write your message here and send it to us