OEM Factory for Rapid Coronavirus Test Kit - Testsea Disease Test Malaria Ab p.f/p.v Tri-line Rapid Test Kit – TESTSEA
OEM Factory for Rapid Coronavirus Test Kit - Testsea Disease Test Malaria Ab p.f/p.v Tri-line Rapid Test Kit – TESTSEA Detail:
Brand Name: |
testsea |
Product name: |
Malaria Ab p.f/p.v tri-line test kit |
Place of Origin: |
Zhejiang, China |
Type: |
Pathological Analysis Equipments |
Certificate: |
ISO9001/13485 |
Instrument classification |
Class II |
Accuracy: |
99.6% |
Specimen: |
Whole Blood |
Format: |
Cassete/Strip |
Specification: |
3.00mm/4.00mm |
MOQ: |
1000 Pcs |
Shelf life: |
2 years |
Allow the test, specimen, buffer and/or controls to reach room temperature 15-30℃ (59-86℉) prior to testing.
1. Bring the pouch to room temperature before opening it. Remove the test device from the sealed pouch and use it as soon as possible.
2. Place the test device on a clean and level surface.
3. For serum or plasma specimen: Hold the dropper vertically and transfer 3 drops of serum or plasma (approximately 100μl) to the specimen well(S) of the test device, then start the timer. See illustration below.
4. For whole blood specimens: Hold the dropper vertically and transfer 1 drop of whole blood(approximately 35μl) to the specimen well(S) of the test device, then add 2 drops of buffer (approximately 70μl) and start the timer. See illustration below.
5. Wait for the colored line(s) to appear. Read results at 15 minutes. Do not interpret the result after 20 minutes.
Applying sufficient amount of specimen is essential for a valid test result. If migration (the wetting of membrane) is not observed in the test window after one minute, add one more drop of buffer (for whole blood) or specimen (for serum or plasma) to the specimen well.
Interpretation of Results
Positive: Two lines appear. One line should always appear in the control line region(C), and another one apparent colored line should appear in the test line region.
Negative: One colored line appears in the control region(C).No apparent colored line appear in the test line region.
Invalid: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure.
★ Review the procedure and repeat the test with a new test device. If the problem persists, discontinue using the test kit immediately and contact your local distributor.
Product detail pictures:
Related Product Guide:
We take pleasure in a really excellent name amongst our shoppers for our exceptional product or service excellent, competitive rate and also the greatest services for OEM Factory for Rapid Coronavirus Test Kit - Testsea Disease Test Malaria Ab p.f/p.v Tri-line Rapid Test Kit – TESTSEA, The product will supply to all over the world, such as: Bulgaria, Luxemburg, Suriname, We look forward to hearing from you, whether you are a returning customer or a new one. We hope you will find what you are looking for here, if not, please contact us immediately. We pride ourselves on top notch customer service and response. Thank you for your business and support!
By Julia from Cannes - 2017.05.02 11:33
It is really lucky to meet such a good supplier, this is our most satisfied cooperation, I think we will work again!
By Alexandra from Lebanon - 2018.06.12 16:22