Human Metapneumovirus Antigen Test Cassette Hmpv Test Kit
Product Detail:
- Sample Type:
- Nasopharyngeal swab, throat swab, or nasopharyngeal aspirate.
- Detection Time:
- 15-20 minutes. Results should be read within 20 minutes to ensure accuracy. Results after this period may be unreliable.
- Sensitivity and Specificity:
- Sensitivity: Typically > 90% for both HMPV and Adenovirus.
- Specificity: Typically > 95% for both viruses, ensuring high accuracy and reliability.
- Storage Conditions:
- Store between 4°C and 30°C, away from light and moisture.
- The shelf life is typically 12-24 months, depending on the manufacturer's guidelines.
Principle:
- Sample Collection:
- Collect a nasopharyngeal or throat swab from the patient using the provided swab stick.
- Test Procedure:
- Step 1: Place the swab into the sample extraction buffer or tube provided.
- Step 2: Mix the swab with the buffer by swirling it in the tube.
- Step 3: Drop the extracted sample onto the sample well of the test cassette.
- Step 4: Wait for 15-20 minutes for the test to develop.
- Result Interpretation:
- After the indicated time, examine the test cassette for lines at the Control (C) and test (T) positions.
- Interpret the results based on the manufacturer's guidelines.
Composition:
Composition |
Amount |
Specification |
IFU |
1 |
/ |
Test cassette |
25 |
Each sealed foil pouch containing one test device and one desiccant |
Extraction diluent |
500μL*1 Tube *25 |
Tris-Cl buffer, NaCl, NP 40, ProClin 300 |
Dropper tip |
/ |
/ |
Swab |
1 |
/ |
Test Procedure:
|
|
5.Carefully remove the swab without touching the tip.Insert the entire tip of the swab 2 to 3 cm into the right nostril.Note the breaking point of the nasal swab.You can feel this with your fingers when inserting the nasal swab or check it in the mimnor. Rub the inside of the nostril in circular movements 5 times for at least 15 seconds,Now take the same nasal swab and insert it into the other nostril.Swab the inside of the nostril in a circular motion 5 times for at least 15 seconds. Please perform the test directly with the sample and do not
|
6.Place the swab in the extraction tube.Rotate the swab for about 10 seconds,Rotate the swab against the extraction tube,pressing the head of the swab against the inside of the tube while squeezing the sides of the tube to release as much liquid as possible from the swab. |
7. Take out the swab from the package without touching the padding. |
8.Mix thoroughly by flicking the bottom of the tube.Place 3 drops of the sample vertically into the sample well of the test cassette.Read the result after 15 minutes. Note:Read the result within 20 minutes.Otherwise,are petition of the test is recommended. |