We always continually provide you with the most conscientious customer service, and the widest variety of designs and styles with finest materials. These efforts include the availability of customized designs with speed and dispatch for Coronavirus Human Test Kit , Hep C Antibody , Human Coronavirus Test , You would not have any communication problem with us. We sincerely welcome prospects all around the globe to call us for business enterprise cooperation.
Good User Reputation for Hav Test - SARS-CoV-2 Neutralizing Antibody Detection Kit (ELISA) – TESTSEA Detail:

PRINCIPLE

The SARS-CoV-2 Neutralizing Antibody Detection Kit is based on competitive ELISA methodology.

Using purified receptor binding domain (RBD), protein from the viral spike (S) protein and the host cell

receptor ACE2, this test is designed to mimic the virus-host neutralizing interaction.

Calibrators, Quality Controls, and serum or plasma samples are individually mixed well in dilution

buffer containing hACE2-HRP conjugate aliquoted in small tubes. Then the mixtures are transferred in

the microplate wells containing immobilized recombinant SARS-CoV-2 RBD fragment (RBD)for

incubation. During the 30-minute incubation, the RBD specific antibody in the calibrators, QC and

samples will compete with the hACE2-HRP for specific binding the RBD immobilized in the wells. After

the incubation, the wells are washed 4 times to remove unbound hACE2-HRP conjugate. A solution of

TMB is then added and incubated for 20 minutes at room temperature, resulting in the development of a

blue color. The color development is stopped with the addition of 1N HCl, and the absorbance is

measured spectrophotometrically at 450 nm. The intensity of the color formed is proportional to the

amount of enzyme present, and is inversely related to the amount of standards assayed in the same way.

Through comparison with the calibration curve formed by the provided calibrators, the concentration of

neutralizing antibodies in the unknown sample is then calculated.

1
2

MATERIALS REQUIRED BUT NOT PROVIDED

1. Distilled or deionized water

2. Precision pipettes: 10μL, 100μL,200μL and 1 mL

3. Disposable pipette tips

4. Microplate reader capable of reading absorbance at 450nm.

5. Absorbent paper

6. Graph paper

7. Vortex mixer or equivalent

SPECIMEN COLLECTION AND STORAGE

1. Serum and Plasma samples collected in tubes containing K2-EDTA can be used for this kit.

2. Specimens should be capped and may be stored for up to 48 hours at 2 °C – 8 °C prior to assaying.

Specimens held for a longer time (up to 6 months) should be frozen only once at -20 °C prior to assay.

Avoid repeated freeze-thaw cycles.

PROTOCOL

3

Reagent Preparation

1. All reagents must be taken out from refrigeration and allowed to return to room temperature before use

(20° to 25°C). Save all reagents in refrigerator promptly after use.

2. All samples and controls should be vortexed before use.

3. hACE2-HRP Solution Preparation: Dilute hACE2-HRP concentrate at 1: 51 dilution ratio with Dilution

Buffer. For example, dilute 100 μL of hACE2-HRP concentrate with 5.0mL of HRP Dilution Buffer to

make a hACE2-HRP solution.

4. 1× Wash Solution Preparation: Dilute the 20× Wash Solution with deionized or distilled water with a

volume ratio of 1:19. For example, dilute 20 mL of 20× Wash Solution with 380 mL of deionized or

distilled water to make 400 mL of 1× Wash Solution.

Test Procedure

1. In separate tubes, aliquot 120μL of the prepared hACE2-HRP Solution.

2. Add 6 μL of calibrators, unknown samples, quality controls in each tube and mix well.

3. Transfer 100μL of each mixture prepared in the step 2 into corresponding microplate wells according

to predesigned test configuration.

3. Cover the plate with Plate Sealer and incubate at 37°C for 30 minutes.

4. Remove the Plate Sealer and wash the plate with approximately 300 μL of 1× Wash Solution per wellfor four times.

5. Tap the plate on paper towel to remove residual liquid in the wells after washing steps.

6. Add 100 μL of TMB Solution to each well and incubate the plate in dark at 20 – 25°C for 20 minutes.

7. Add 50 μL of Stop Solution to each well to stop the reaction.

8. Read the absorbance in microplate reader at 450 nm within 10 minutes (630nm as accessory is

recommended for higher precision performance).


Product detail pictures:

Good User Reputation for Hav Test - SARS-CoV-2 Neutralizing Antibody Detection Kit (ELISA) – TESTSEA detail pictures


Related Product Guide:

Reliable good quality and very good credit standing are our principles, which will help us at a top-ranking position. Adhering to your tenet of "quality 1st, purchaser supreme" for Good User Reputation for Hav Test - SARS-CoV-2 Neutralizing Antibody Detection Kit (ELISA) – TESTSEA, The product will supply to all over the world, such as: Guyana, Spain, Puerto Rico, All the employees in factory, store, and office are struggling for one common goal to provide better quality and service. Real business is to get win-win situation. We would like to provide more support for customers. Welcome all nice buyers to communicate details of our products with us!
  • The factory workers have a good team spirit, so we received high quality products fast, in addition, the price is also appropriate, this is a very good and reliable Chinese manufacturers.
    5 Stars By Ivan from Argentina - 2017.08.18 18:38
    The supplier cooperation attitude is very good, encountered various problems, always willing to cooperate with us, to us as the real God.
    5 Stars By Eric from Lithuania - 2018.11.04 10:32

    Send your message to us:

    Write your message here and send it to us

    Related Products

    Send your message to us:

    Write your message here and send it to us