While using the "Client-Oriented" organization philosophy, a rigorous top quality command process, highly developed production devices and a potent R&D workforce, we normally provide high quality products, outstanding solutions and aggressive charges for Malaria Rapid Diagnostic Test Kit , Coronavirus Test Kits , Rapid Test Device Human Coronavirus , We welcome new and previous clients from all walks of lifestyle to get in touch with us for long term business relationships and mutual accomplishment!
Factory source Rapid Chlamydia Test Cvs - COVID-19 Antigen Test Cassette (Nasal Swab Specimen) – TESTSEA Detail:

The COVID-19 Antigen Test Cassette is a rapid chromatographic immunoassay for the qualitative detection of COVID-19 antigen in nasal swab specimen to aid in the diagnosis of COVID-19 viral infection.

/covid-19-antigen-test-cassette-nasal-swab-specimen-product/

 

 

image001 image002

How to collect the specimens?

Specimens obtained early during symptom onset will contain the highest viral titers; specimens obtained after five days of symptoms are more likely to produce negative results when compared to an RT-PCR assay. Inadequate specimen collection, improper specimen handling and/or transport may yield a falsely negative result; therefore, training in specimen collection is highly recommended due to the importance of specimen quality for generating accurate test results. Sample Collection

Nasopharyngeal Swab Sample Insert minitip swab with a flexible shaft (wire or plastic) through the nostril parallel to the palate (not upwards) until resistance is encountered or the distance is equivalent to that from the ear to the nostril of the patient, indicating contact with the nasopharynx. Swab should reach depth equal to distance from nostrils to outer opening of the ear. Gently rub and roll the swab. Leave swab in place for several seconds to absorb secretions. Slowly remove swab while rotating it. Specimens can be collected from both sides using the same swab, but it is not necessary to collect specimens from both sides if the minitip is saturated with fluid from the first collection. If a deviated septum or blockage creates difficulty in obtaining the specimen from one nostril, use the same swab to obtain the specimen from the other nostril.

image003

How to test ?

Allow the test, specimen, buffer and/or controls to reach room temperature 15-30℃ (59-86℉) prior to testing.

1.Bring the pouch to room temperature before opening it. Remove the test device from the sealed pouch and use it as soon as possible.

2.Place the test device on a clean and level surface.

3.Unscrew the cap of the specimen buffer,push and rotate the swab with sample in the buffer tube. Rotate (twirl) swab shaft 10 times.

4.Hold the dropper vertically and transfer 3 drops of specimen solution (approximately 100μl) to the specimen well(S), then start the timer. See illustration below.

Wait for the colored line(s) to appear. Read results at 10 minutes. Do not interpret the result after 20 minutes.

image004 image005

INTERPRETATION OF RESULTS

Positive: Two lines appear. One line should always appear in the control line region(C), and another one apparent colored line should appear in the test line region.

*NOTE: The intensity of the color in the test line regions may vary depending on the concentration of COVID-19 antibodies present in the specimen. Therefore, any shade of color in the test line region should be considered positive.

Negative: One colored line appears in the control region(C).No apparent colored line appear in the test line region.

Invalid: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test device. If the problem persists, discontinue using the test kit immediately and contact your local distributor.


Product detail pictures:

Factory source Rapid Chlamydia Test Cvs - COVID-19 Antigen Test Cassette (Nasal Swab Specimen) – TESTSEA detail pictures

Factory source Rapid Chlamydia Test Cvs - COVID-19 Antigen Test Cassette (Nasal Swab Specimen) – TESTSEA detail pictures

Factory source Rapid Chlamydia Test Cvs - COVID-19 Antigen Test Cassette (Nasal Swab Specimen) – TESTSEA detail pictures

Factory source Rapid Chlamydia Test Cvs - COVID-19 Antigen Test Cassette (Nasal Swab Specimen) – TESTSEA detail pictures


Related Product Guide:

Our company puts emphasis on the management, the introduction of talented personnel, and the construction of staff building, trying hard to improve the quality and liability consciousness of staff members. Our company successfully attained IS9001 Certification and European CE Certification of Factory source Rapid Chlamydia Test Cvs - COVID-19 Antigen Test Cassette (Nasal Swab Specimen) – TESTSEA, The product will supply to all over the world, such as: UK, Marseille, Romania, We have customers from more than 20 countries and our reputation has been recognized by our esteemed customers. Never-ending improvement and striving for 0% deficiency are our two main quality policies. Should you need anything, don't hesitate to contact us.
  • A good manufacturers, we have cooperated twice, good quality and good service attitude.
    5 Stars By Rosalind from Israel - 2017.03.28 16:34
    After the signing of the contract, we received satisfactory goods in a short term, this is a commendable manufacturer.
    5 Stars By Eric from Johor - 2017.11.01 17:04

    Send your message to us:

    Write your message here and send it to us

    Related Products

    Send your message to us:

    Write your message here and send it to us