We persist with the principle of "quality 1st, assistance initially, continual improvement and innovation to meet the customers" for your management and "zero defect, zero complaints" as the standard objective. To great our service, we present the products and solutions while using the very good top quality at the reasonable cost for Dengue Fever Test Kit , 2019-Ncov Rapid Test Coronavirus , Coronavirus Antibody Test , We adhere to the tenet of "Services of Standardization, to Meet Customers' Demands".
Factory Free sample Simple Test Kit For New Coronavirus - COVID-19 ANTIGEN TEST CASSETTE(SWAB) – TESTSEA Detail:

11

13

INTENDED USE

Testsealabs®COVID-19 Antigen Test Cassette is a rapid chromatographic immunoassay for the qualitative detection of COVID-19 antigen in nasal swab specimen to aid in the diagnosis of COVID-19 viral infection.  

Specification

20pc/box (20 test devices+ 20 Extraction Tubes+1 Extraction Buffer+ 20 Sterilized Swabs+1 Product Insert)

111

MATERIALS PROVIDED

1.Test Devices
2.Extraction Buffer
3.Extraction Tube
4.Sterilized Swab
5.Work Station
6.Package Insert

SPECIMENS COLLECTION

Insert mini tip swab with a flexible shaft (wire or plastic) through the nostril parallel to the palate (not upwards) until resistance is encountered or the distance is equivalent to that from the ear to the nostril of the patient, indicating contact with the nasopharynx. Swab should reach depth equal to distance from nostrils to outer opening of the ear. Gently rub and roll the swab. Leave swab in place for several seconds to absorb secretions. Slowly remove swab while rotating it. Specimens can be collected from both sides using the same swab, but it is not necessary to collect specimens from both sides if the minitip is saturated with fluid from the first collection. If a deviated septum or blockage creates difficulty in obtaining the specimen from one nostril, use the same swab to obtain the specimen from the other nostril.

HOW TO TEST

Allow the test, specimen, buffer and/or controls to reach room temperature 15-30℃ (59-86℉) prior to testing.

1.Place the Extraction Tube in the workstation. Hold the extraction reagent bottle upside down 

117

vertically. Squeeze the bottle and let the solution drop into the extraction tube freely without touching the edge of the tube. Add 10 drops of solution to the Extraction Tube.

2.Place the swab specimen in the Extraction Tube. Rotate the swab for approximately 10 seconds while pressing the head against the inside of the tube to release the antigen in the swab.

3. Remove the swab while squeezing the swab head against the inside of the Extraction Tube as you remove it to expel as much liquid as possible from the swab. Discard the swab in accordance with your biohazard waste disposal protocol.

4.Cover the tube with cap,then add 3 drops of the sample into the sample hole vertically.

5.Read the result after 15 minutes. If left unread for 20 minutes or more the results are invalid and a repeat test is recommended.

INTERPRETATION OF RESULTS

Positive: Two lines appear. One line should always appear in the control line region(C), and another one apparent colored line should appear in the test line region.

*NOTE: The intensity of the color in the test line regions may vary depending on the concentration of COVID-19 antibodies present in the specimen. Therefore, any shade of color in the test line region should be considered positive.

Negative: One colored line appears in the control region(C).No apparent colored line appear in the test line region.

Invalid: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure. Review the procedure and repeat the test with a new test device. If the problem persists, discontinue using the test kit immediately and contact your local distributor.

117

INTERPRETATION OF RESULTS

 118

Positive: Two lines appear. One line should always appear in the control line region(C), and another one apparent colored line should appear in the test line region.

*NOTE: The intensity of the color in the test line regions may vary depending on the concentration of COVID-19 antibodies present in the specimen. Therefore, any shade of color in the test line region should be considered positive.

Negative: One colored line appears in the control region(C).No apparent colored line appear in the test line region.


Product detail pictures:

Factory Free sample Simple Test Kit For New Coronavirus - COVID-19 ANTIGEN TEST CASSETTE(SWAB) – TESTSEA detail pictures


Related Product Guide:

"Control the standard by the details, show the power by quality". Our firm has strived to establish a extremely efficient and stable employees crew and explored an effective excellent command method for Factory Free sample Simple Test Kit For New Coronavirus - COVID-19 ANTIGEN TEST CASSETTE(SWAB) – TESTSEA, The product will supply to all over the world, such as: Oman, UAE, Rome, Our company is working by the operation principle of "integrity-based, cooperation created, people oriented, win-win cooperation". We hope we can have a friendly relationship with businessman from all over the world.
  • The after-sale warranty service is timely and thoughtful, encounter problems can be resolved very quickly, we feel reliable and secure.
    5 Stars By Nicci Hackner from Singapore - 2018.07.27 12:26
    Speaking of this cooperation with the Chinese manufacturer, I just want to say"well dodne", we are very satisfied.
    5 Stars By Rose from Iran - 2018.06.18 19:26

    Send your message to us:

    Send your message to us:

    Write your message here and send it to us