China OEM Veterinary Rapid Test Kits - SARS-CoV-2 Neutralizing Antibody Detection Kit (ELISA) – TESTSEA

Short Description:


Product Detail

Product Tags

Related Video

Feedback (2)

Our advancement depends on the superior gear ,superb talents and consistently strengthened technology forces for Canine Coronavirus Test , Syphilis Test , New Corona Virus Coronavirus Antibody Test , We've been prepared to cooperate with company friends from at your home and overseas and produce a wonderful future with each other.
China OEM Veterinary Rapid Test Kits - SARS-CoV-2 Neutralizing Antibody Detection Kit (ELISA) – TESTSEA Detail:

PRINCIPLE

The SARS-CoV-2 Neutralizing Antibody Detection Kit is based on competitive ELISA methodology.

Using purified receptor binding domain (RBD), protein from the viral spike (S) protein and the host cell

receptor ACE2, this test is designed to mimic the virus-host neutralizing interaction.

Calibrators, Quality Controls, and serum or plasma samples are individually mixed well in dilution

buffer containing hACE2-HRP conjugate aliquoted in small tubes. Then the mixtures are transferred in

the microplate wells containing immobilized recombinant SARS-CoV-2 RBD fragment (RBD)for

incubation. During the 30-minute incubation, the RBD specific antibody in the calibrators, QC and

samples will compete with the hACE2-HRP for specific binding the RBD immobilized in the wells. After

the incubation, the wells are washed 4 times to remove unbound hACE2-HRP conjugate. A solution of

TMB is then added and incubated for 20 minutes at room temperature, resulting in the development of a

blue color. The color development is stopped with the addition of 1N HCl, and the absorbance is

measured spectrophotometrically at 450 nm. The intensity of the color formed is proportional to the

amount of enzyme present, and is inversely related to the amount of standards assayed in the same way.

Through comparison with the calibration curve formed by the provided calibrators, the concentration of

neutralizing antibodies in the unknown sample is then calculated.

1
2

MATERIALS REQUIRED BUT NOT PROVIDED

1. Distilled or deionized water

2. Precision pipettes: 10μL, 100μL,200μL and 1 mL

3. Disposable pipette tips

4. Microplate reader capable of reading absorbance at 450nm.

5. Absorbent paper

6. Graph paper

7. Vortex mixer or equivalent

SPECIMEN COLLECTION AND STORAGE

1. Serum and Plasma samples collected in tubes containing K2-EDTA can be used for this kit.

2. Specimens should be capped and may be stored for up to 48 hours at 2 °C – 8 °C prior to assaying.

Specimens held for a longer time (up to 6 months) should be frozen only once at -20 °C prior to assay.

Avoid repeated freeze-thaw cycles.

PROTOCOL

3

Reagent Preparation

1. All reagents must be taken out from refrigeration and allowed to return to room temperature before use

(20° to 25°C). Save all reagents in refrigerator promptly after use.

2. All samples and controls should be vortexed before use.

3. hACE2-HRP Solution Preparation: Dilute hACE2-HRP concentrate at 1: 51 dilution ratio with Dilution

Buffer. For example, dilute 100 μL of hACE2-HRP concentrate with 5.0mL of HRP Dilution Buffer to

make a hACE2-HRP solution.

4. 1× Wash Solution Preparation: Dilute the 20× Wash Solution with deionized or distilled water with a

volume ratio of 1:19. For example, dilute 20 mL of 20× Wash Solution with 380 mL of deionized or

distilled water to make 400 mL of 1× Wash Solution.

Test Procedure

1. In separate tubes, aliquot 120μL of the prepared hACE2-HRP Solution.

2. Add 6 μL of calibrators, unknown samples, quality controls in each tube and mix well.

3. Transfer 100μL of each mixture prepared in the step 2 into corresponding microplate wells according

to predesigned test configuration.

3. Cover the plate with Plate Sealer and incubate at 37°C for 30 minutes.

4. Remove the Plate Sealer and wash the plate with approximately 300 μL of 1× Wash Solution per wellfor four times.

5. Tap the plate on paper towel to remove residual liquid in the wells after washing steps.

6. Add 100 μL of TMB Solution to each well and incubate the plate in dark at 20 – 25°C for 20 minutes.

7. Add 50 μL of Stop Solution to each well to stop the reaction.

8. Read the absorbance in microplate reader at 450 nm within 10 minutes (630nm as accessory is

recommended for higher precision performance).


Product detail pictures:

China OEM Veterinary Rapid Test Kits - SARS-CoV-2 Neutralizing Antibody Detection Kit (ELISA) – TESTSEA detail pictures


Related Product Guide:

Every single member from our higher effectiveness product sales staff values customers' requires and organization communication for China OEM Veterinary Rapid Test Kits - SARS-CoV-2 Neutralizing Antibody Detection Kit (ELISA) – TESTSEA, The product will supply to all over the world, such as: Hyderabad, Indonesia, Malaysia, Insisting on the high quality generation line management and customers expert assistance, we now have designed our resolution to supply our buyers using the to start with amount getting and just after services practical experience. Maintaining the prevailing friendly relations with our buyers, we however innovate our solution lists all of the time to satisfy the brand new demands and adhere to the most up-to-date development of the market in Malta. We have been ready to face the worries and make the improve to understand all the possibilities in international trade.
  • The goods we received and the sample sales staff display to us have the same quality, it is really a creditable manufacturer.
    5 Stars By Riva from Guatemala - 2018.06.18 19:26
    The company has a good reputation in this industry, and finally it tured out that choose them is a good choice.
    5 Stars By Hellyngton Sato from Egypt - 2017.11.29 11:09

    Send your message to us:

    Write your message here and send it to us

    Related Products

    Send your message to us:

    Write your message here and send it to us