2020 China New Design Human Use Coronavirus Disease Detection Kit - Testsea Disease Test H.pylori Ab Rapid Test Kit – TESTSEA
2020 China New Design Human Use Coronavirus Disease Detection Kit - Testsea Disease Test H.pylori Ab Rapid Test Kit – TESTSEA Detail:
Brand Name: |
testsea |
Product name: |
H.Pylori Ab Test |
Place of Origin: |
Zhejiang, China |
Type: |
Pathological Analysis Equipments |
Certificate: |
ISO9001/13485 |
Instrument classification |
Class II |
Accuracy: |
99.6% |
Specimen: |
Whole Blood/Serum/Plasma |
Format: |
Cassete/Strip |
Specification: |
3.00mm/4.00mm |
MOQ: |
1000 Pcs |
Shelf life: |
2 years |
Allow the test, specimen, buffer and/or controls to reach room temperature 15-30℃ (59-86℉) prior to testing.
1. Bring the pouch to room temperature before opening it. Remove the test device from the sealed pouch and use it as soon as possible.
2. Place the test device on a clean and level surface.
3. For serum or plasma specimen: Hold the dropper vertically and transfer 3 drops of serum or plasma (approximately 100μl) to the specimen well(S) of the test device, then start the timer. See illustration below.
4. For whole blood specimens: Hold the dropper vertically and transfer 1 drop of whole blood(approximately 35μl) to the specimen well(S) of the test device, then add 2 drops of buffer (approximately 70μl) and start the timer. See illustration below.
5. Wait for the colored line(s) to appear. Read results at 15 minutes. Do not interpret the result after 20 minutes.
Applying sufficient amount of specimen is essential for a valid test result. If migration (the wetting of membrane) is not observed in the test window after one minute, add one more drop of buffer (for whole blood) or specimen (for serum or plasma) to the specimen well.
Interpretation of Results
Positive: Two lines appear. One line should always appear in the control line region(C), and another one apparent colored line should appear in the test line region.
Negative: One colored line appears in the control region(C).No apparent colored line appear in the test line region.
Invalid: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for control line failure.
★ Review the procedure and repeat the test with a new test device. If the problem persists, discontinue using the test kit immediately and contact your local distributor.
Product detail pictures:
Related Product Guide:
We support our purchasers with ideal premium quality products and substantial level company. Becoming the specialist manufacturer in this sector, we've acquired rich practical working experience in producing and managing for 2020 China New Design Human Use Coronavirus Disease Detection Kit - Testsea Disease Test H.pylori Ab Rapid Test Kit – TESTSEA, The product will supply to all over the world, such as: French, Jeddah, United Arab Emirates, Good quality and reasonable price have brought us stable customers and high reputation. Providing 'Quality Products, Excellent Service, Competitive Prices and Prompt Delivery', we are now looking forward to even greater cooperation with overseas customers based on mutual benefits. We will work whole-heartedly to improve our products and services. We also promise to work jointly with business partners to elevate our cooperation to a higher level and share success together. Warmly welcome you to visit our factory sincerely.